Logotipo del repositorio
Comunidades y Colecciones
Estadísticas
Cosmosnew
  1. Inicio
  2. Producción Científica UPeU
  3. Publicaciones
  4. Reduction of cracks in concrete slabs through the incorporation of polypropylene synthetic fiber
Cargando...
Miniatura

Reduction of cracks in concrete slabs through the incorporation of polypropylene synthetic fiber

Author(s)
Ramos Eugenio, Max Leonel  
Universidad Peruana Unión  
Parillo Escarsena, Edwin  
Universidad Peruana Unión  
Date Issued
2026
Type
Article
Publisher
Gruppo Italiano Frattura
Volume
20
Issue
75
Series/Report No.
Frattura ed Integrità Strutturale
Contained in
Fracture and Structural Integrity
Start Page
399
End Page
434
DOI
10.3221/IGF-ESIS.75.29
ISSN
1971-8993
Abstract
In Peru, research on cracking in concrete slabs has been limited, partly due to the perception that cracks do not pose an immediate problem. However, their cumulative effect over the long term can compromise structural durability, highlighting the need for further study. This research was conducted according to the recommendations of ASTM C1579, which establishes procedures for evaluating shrinkage cracking in concrete mixes with and without fiber reinforcement. The main objective was to determine the optimal proportion of polypropylene synthetic fiber that maximizes the reduction in the appearance and formation of cracks. Three dosages were evaluated: DM-01 (500 g/m³), DM-02 (1000 g/m³), and DM-03 (2000 g/m³), compared to a reference concrete (MP) during a 35-day curing period. The results indicated that dosage DM-02 (1000 g/m³) exhibited the best performance, with reductions of 18.41% in average crack thickness, 11.46% in total crack length, and 32.43% in the number of cracks compared to the control concrete. Furthermore, the Mann-Whitney U test applied to DM-02 and MP showed that the average crack thickness at 28 days (p = 0.073) showed a trend toward statistical significance, suggesting a possible reduction in crack thickness with the addition of fibers. In contrast, mixes DM-01 and DM-03 showed heterogeneous results, without substantial improvements in any of the variables; in particular, DM-03 registered an increase in crack thickness. It is concluded that a moderate fiber dosage (DM-02) is the most suitable option, since both a deficiency and an excess of fiber can compromise the material's effectiveness against cracking.
Keywords

Fatigue - Crack Growt...

Fiber

Concrete

Width

Length

Crack

Polypropylene

Metrics
Red de relaciones
PersonasOrganizacionesProyectosFinanciamientosProducción científicaPatentesProductosEventosEquipamientoInstalacionesServiciosCVTitulacionesMedicionesIndicadoresDatos
PersonasOrganizacionesProyectosFinanciamientosProducción científicaPatentesProductosEventosEquipamientoInstalacionesServiciosCVTitulacionesMedicionesIndicadoresDatos
Universidad Peruana Unión

CRIS UPeU integra y gestiona la producción científica, investigadores, proyectos, financiamientos, patentes y resultados de I+D+i de la Universidad Peruana Unión, e interopera con PerúCRIS (CONCYTEC) mediante el estándar CERIF · OpenAIRE.

Interopera con PerúCRISCERIF · OpenAIRE

Contacto

  • Carretera Central km 19
  • Ñaña, Lima, Perú
  • +51 998 801 168
  • repositorio@upeu.edu.pe

Horario de atención

  • Lunes a Jueves8:00–12:30 · 14:00–18:00
  • Viernes8:00–13:00
CampusLima · Juliaca · Tarapoto

Interoperabilidad CRIS

  • PerúCRIS
  • Directrices PerúCRIS
  • Modelo CERIF (euroCRIS)
  • CONCYTEC
  • Portal UPeU

footer.built-with footer.link.dspace-cris footer.extension-by footer.link.4science· Diseño por SciBack

  • Accessibility settings
  • Política de privacidad
  • Acuerdo de usuario final