Cruz Huaranga, Milda Amparo
Cargando...
Nombre preferido
Cruz Huaranga, Milda Amparo
Nombre oficial
Cruz Huaranga, Milda Amparo
Nombre alternativo
Cruz Huaranga, Milda A.
Afiliación principal
Universidad Peruana Unión
ORCID
ID de autor de Scopus
4 resultados
Mostrando 1 - 4 de 4
- Algunas métricas están bloqueadas por suconfiguración de consentimiento
Item type:Publicación, Tratamiento primario de aguas servidas mediante tanque séptico en urbanización de Lurigancho, Lima(2018-12-19) ;Aguirre Solis, Sarita ;Vargas Urbano, Miqueas ;Zeron Cancha, Migumi; Un problema latente en el mundo, cuya resolución aún viene siendo estudiada es el tratamiento y disposición final de los residuos líquidos provenientes del uso doméstico, comercial o industrial. En zonas rurales o urbanas que no poseen un sistema de alcantarillado, o en zonas que por la distancia no justifica su instalación, una alternativa de tratamiento primario es el empleo del sistema de tanque séptico, que es un depósito cerrado (rectangular o circular) donde las aguas servidas son fermentadas de manera anaerobia de uno a tres días, resultado de ello la disposición de agua, gas metano, bióxido de carbono y lodos, productos que podrían tener múltiples usos. El proyecto piloto se ejecutó a escala real empleando un tanque séptico y se realizó en una vivienda familiar del distrito de Lurigancho-Chosica (Lima). El objetivo de este trabajo fue mejorar la calidad del agua, considerando los parámetros fisicoquímicos (sólidos suspendidos totales, turbiedad, pH, oxígeno disuelto, conductividad, DBO5, y biológicos (coliformes totales y fecales). Para la construcción del tanque séptico se realizó la excavación en un área de 0.88 m2 con una profundidad de 1.7 m; para la construcción de las paredes y las cámaras se utilizaron ladrillos y mezcla de cemento y arena fina, además para la conexión de las tuberías provenientes de la cocina y servicios, se utilizaron tuberías de 2” y 4” de diámetro. El tanque se recubrió con una capa de plástico y una plancha de tecnopor (1.05 x 0.75 m), como medida de seguridad se elaboró una tapa de madera. Los parámetros fisicoquímicos y biológicos se analizaron en laboratorio. Se concluye que el prototipo a escala real del tanque séptico, tiene una eficiencia de 63.12 % de funcionamiento con un proceso de retención de 3 días, un caudal de 4.624x106 m3 /s y un volumen depositado de 0.216 m3.Citas (OpenAlex): 0metric-badges.view 1 - Algunas métricas están bloqueadas por suconfiguración de consentimiento
Item type:Publicación, Quantitative Analysis of Climatic Variability in Relation to Surface Loss with Landsat Data in Peruvian Snow-Capped Mountains 2010–2020(2022-01-01) ;Flores Kancha, Anthony ;Torres Agüero, Jair; ; Climate change is affecting the planet due to lack of information regarding its temperatures, precipitation and decrease in the surface area of the snow-capped mountains, which causes a high impact on the melting of the snow-capped mountains, for this reason it is...Citas (OpenAlex): 0metric-badges.view 5 - Algunas métricas están bloqueadas por suconfiguración de consentimiento
Item type:Publicación, Adsorption of hydrogen sulfide by activated carbon produced by regeneration of sludge from upflow anaerobic sludge blanket(Latvia University of Life Sciences and Technologies, 2022-05-25); ; The objective of this study was to determine the efficiency of H2S adsorption by activated carbon obtained from the regeneration of sludge from an Upflow Anaerobic Sludge Blanket (UASB).The H2S adsorption system was carried out in the Chemistry laboratory of the Universidad Peruana Unión, the inflow of the fixed bed towers was 4 L•min -1 and 36 g of adsorbent media (6 different Active Carbon (AC), depending on Pyrolization temperatures (PT) and [M] KOH), AC at PT 700 ºC/1M, AC PT 500 ºC/4M, AC PT 500 ºC/1M, AC PT 700 ºC/4Mand AC PT 600 ºC/2.5 M the last with two repetitions.The adsorption of H2S was determined by the volumetric oxidation-reduction method.The parameter of the greatest influence for the adsorption of H2S was PT at 99 and 90% CI respectively, demonstrated by 22 and 32 factorial designs; satisfactory elimination efficiencies of H2S were obtained and reached 94% during a retention time of 20 minutes of activated carbon at PT 700 ºC and [1M] KOH.For the response surface prediction simulation, the optimized parameters for the removal of H2S approximately greater than 96% was at PT of 635 ºC and activating agent of [2.6 M] KOH.Therefore, the adsorption of H2S by activated carbons for sludge is a new, viable and sustainable alternative for the environment.Citas (OpenAlex): 2metric-badges.view 2 - Algunas métricas están bloqueadas por suconfiguración de consentimiento
Item type:Publicación, Fitorremediación mediante las especies palustre y flotante, Zantedeschia aethiopica y Eichhornia crassipes en el tratamiento de aguas residuales domésticas en la zona de la región natural Quechua-Cajamarca(2019-12-18) ;Nuñez Morales, Erlin; La investigación tuvo el propósito de evaluar la eficiencia del sistema de fitorremediación mediante las especies palustre (Zantedeschia aethiopica) y flotante (Eichhornia crassipes) en el tratamiento de aguas residuales domésticas en la región natural Quechua-Cajamarca, para ello se ubicó el punto de captación y la ubicación del proyecto, posteriormente se diseñó e implementó el sistema de tratamiento considerando infiltraciones en el humedal subsuperficial horizontal que contuvo al sustrato, el agua a tratar, la especie Zantedeschia aethiopica con las medidas (ancho = 1.16 m, largo = 2.32 m, altura = 0.5 m) seguido del humedal superficial compuesto por el agua a tratar y la especie Eichhornia crassipes (ancho = 1.39 m, largo = 2.78 m, altura = 0.40 m). El tratamiento duró 90 días, luego se monitoreo en la entrada y salida los parámetros fisicoquímicos y microbiológicos cuyos resultados de remoción dieron para Aceites y grasas 76%, DBO5 95%, DQO 92%, SST 95%, turbidez 96%, N-NH3 64%, Conductividad 59%, y los valores más bajos fueron Color 34% y CTT 22%. En el análisis, el LMP que no cumplió únicamente fue CTT y los demás sí, no obstante para los ECA cumplieron Aceites y Grasas, Color, Conductividad, temperatura, pH, SST, turbidez, y aquellos que no cumplieron N-NH3, DBO5, DQO, OD y CTT. En conclusión se alcanzó un 70% de eficiencia de remoción, los parámetros que no lograron la remoción adecuada para cumplir el LMP y ECA por completo indican la necesidad de implementar un tratamiento primario.Citas (OpenAlex): 1metric-badges.view 8